Error Code E PS
PSD (Position Sensor Device) sensor error — malfunction of PSD sensor
Moderate
Address soon - your appliance may not work properly
Also displayed as: E PS
How to Fix
- 1
Step 1: Check connector between Sub PCB and PSD sensor for loose or disconnected connection. If loose, reconnect or repair.
- 2
Step 2: Measure voltage at CON2 5th Pin ~ 7th Pin. Expected: 4.75 ~ 5.25V. If NOT within spec, replace Sub PCB.
- 3
Step 3: Measure signal voltage at CON2 6th Pin ~ 7th Pin. Expected: Not 0 or 5V (oscillating signal). If reads 0V or 5V (static), replace PSD sensor.
- 4
Step 4: If both voltages are correct, reconnect or repair connector and retest.
Other Error Codes for LRYXC2606B
Defect of ice maker kit — malfunction of in-door ice maker motor
Defect of flow meter or lack of water supply — malfunction of flow meter. Check connection of flow meter and water supply.
Defect of freezer defrost sensor — short-circuit or disconnection of defrost sensor
Defect of freezer craft ice maker sensor — short-circuit or disconnection of craft ice maker sensor
Defect of Mini Cubed ice maker kit — malfunction of Mini Cubed ice maker motor
Defect of refrigerator sensor — short-circuit or disconnection of refrigerator sensor
Defect of freezer sensor — short-circuit or disconnection of freezer sensor
Defect of ice-room sensor or ice maker sensor — short-circuit or disconnection